    "api_version": "1",
    "kind": "dse_post",
    "self": "https://update.dsesecurity.com/api/v1/posts/dse-20260908-008-size-ras-gateway-standby-pools-as-an-explicit-availability-decision/",
    "item": {
        "id": "https://update.dsesecurity.com/updates/dse-20260908-008-size-ras-gateway-standby-pools-as-an-explicit-availability-decision/",
        "slug": "dse-20260908-008-size-ras-gateway-standby-pools-as-an-explicit-availability-decision",
        "url": "https://update.dsesecurity.com/updates/dse-20260908-008-size-ras-gateway-standby-pools-as-an-explicit-availability-decision/",
        "alternate_urls": {
            "markdown": "https://update.dsesecurity.com/updates/dse-20260908-008-size-ras-gateway-standby-pools-as-an-explicit-availability-decision.md",
            "json": "https://update.dsesecurity.com/api/v1/posts/dse-20260908-008-size-ras-gateway-standby-pools-as-an-explicit-availability-decision/"
        },
        "title": "Size RAS gateway standby pools as an explicit availability decision",
        "summary": "How should active and standby gateway membership be reviewed in an SDN RAS pool?",
        "format": {
            "slug": "guide",
            "name": "Guide"
        },
        "priority": {
            "slug": "info",
            "name": "Information"
        },
        "featured": false,
        "image": {
            "theme": "network-infrastructure",
            "label": "Networks & infrastructure",
            "alt": "Resilient network core with engineered blue and gold data paths.",
            "card_url": "https://update.dsesecurity.com/assets/editorial/network-infrastructure-card.webp?v=1.8.20",
            "hero_url": "https://update.dsesecurity.com/assets/editorial/network-infrastructure-hero.webp?v=1.8.20",
            "social_url": "https://update.dsesecurity.com/assets/editorial/network-infrastructure-social-v2.jpg?v=1.8.20",
            "width": 2400,
            "height": 1350
        },
        "topics": [
            {
                "slug": "it",
                "name": "IT",
                "url": "https://update.dsesecurity.com/topic/it/"
            },
            {
                "slug": "networks-infrastructure",
                "name": "Networks & Infrastructure",
                "url": "https://update.dsesecurity.com/topic/networks-infrastructure/"
            }
        ],
        "author": {
            "name": "DSE Security Editorial Team",
            "url": "https://update.dsesecurity.com/#editorial-team",
            "type": "Organization"
        },
        "publisher": {
            "name": "Detection Systems & Engineering",
            "url": "https://dsesecurity.com/"
        },
        "published_at": "2026-09-08T18:17:03+00:00",
        "modified_at": "2026-09-08T18:17:13+00:00",
        "reviewed_on": "2026-09-08",
        "reading_minutes": 1,
        "word_count": 211,
        "potentially_affected": "Use this review for an SDN multitenant gateway design.",
        "dse_recommendation": "Document which active gateway failures the proposed standby allocation must cover.",
        "primary_source": {
            "name": "RAS Gateway High Availability",
            "url": "https://learn.microsoft.com/en-us/windows-server/networking/sdn/technologies/network-function-virtualization/RAS-Gateway-High-Availability",
            "published_on": null,
            "authority": "Microsoft Learn"
        },
        "publishing_principles": "https://update.dsesecurity.com/updates/dse-updates-editorial-methodology/",
        "usage_info": "https://update.dsesecurity.com/usage/",
        "copyright_notice": "Copyright © 2026 Detection Systems & Engineering. All rights reserved.",
        "content_html": "<h2>Source facts</h2>\n<p>Microsoft describes multitenant RAS Gateway as routing traffic between virtual and physical networks for enterprises or service providers. Gateway pools use M active virtual gateways with N standby gateways; N cannot exceed M. In the documented deployment, pools sit behind a software load balancer, and a tenant can have connections ending on different pools or gateways. <a href=\"https://learn.microsoft.com/en-us/windows-server/networking/sdn/technologies/network-function-virtualization/RAS-Gateway-High-Availability\" target=\"_blank\" rel=\"noopener noreferrer\">Microsoft documentation</a>.</p>\n<h2>Applicability</h2>\n<p>Use this review for an SDN multitenant gateway design. Identify the intended gateway function, pool membership, and tenant connection paths. Confirm the current supported deployment requirements before applying the architectural example.</p>\n<h2>DSE recommendation</h2>\n<p>Document which active gateway failures the proposed standby allocation must cover. Name the tenant connections that would be included in a controlled failover exercise and the acceptable interruption for each. Ask the network owner to review placement and available capacity alongside the gateway count. Preserve the original pool design and assign responsibility for restoring standby capacity after an incident.</p>\n<h2>Verification</h2>\n<p>During an approved exercise, record active and standby membership before and after the selected failure. Test representative tenant connections and compare the interruption with the approved objective. Check the restored steady state separately from initial recovery. Retain unsuccessful connections and capacity concerns as findings requiring follow-up.</p>\n<h2>Official references</h2>\n<p><a href=\"https://learn.microsoft.com/en-us/windows-server/networking/sdn/technologies/network-function-virtualization/RAS-Gateway-High-Availability\" target=\"_blank\" rel=\"noopener noreferrer\">Microsoft Learn: RAS Gateway High Availability</a>. Source reviewed September 8, 2026.</p>",
        "content_text": "Source facts\nMicrosoft describes multitenant RAS Gateway as routing traffic between virtual and physical networks for enterprises or service providers. Gateway pools use M active virtual gateways with N standby gateways; N cannot exceed M. In the documented deployment, pools sit behind a software load balancer, and a tenant can have connections ending on different pools or gateways. Microsoft documentation.\nApplicability\nUse this review for an SDN multitenant gateway design. Identify the intended gateway function, pool membership, and tenant connection paths. Confirm the current supported deployment requirements before applying the architectural example.\nDSE recommendation\nDocument which active gateway failures the proposed standby allocation must cover. Name the tenant connections that would be included in a controlled failover exercise and the acceptable interruption for each. Ask the network owner to review placement and available capacity alongside the gateway count. Preserve the original pool design and assign responsibility for restoring standby capacity after an incident.\nVerification\nDuring an approved exercise, record active and standby membership before and after the selected failure. Test representative tenant connections and compare the interruption with the approved objective. Check the restored steady state separately from initial recovery. Retain unsuccessful connections and capacity concerns as findings requiring follow-up.\nOfficial references\nMicrosoft Learn: RAS Gateway High Availability. Source reviewed September 8, 2026.",
        "content_markdown": "## Source facts\n\nMicrosoft describes multitenant RAS Gateway as routing traffic between virtual and physical networks for enterprises or service providers. Gateway pools use M active virtual gateways with N standby gateways; N cannot exceed M. In the documented deployment, pools sit behind a software load balancer, and a tenant can have connections ending on different pools or gateways. [Microsoft documentation](https://learn.microsoft.com/en-us/windows-server/networking/sdn/technologies/network-function-virtualization/RAS-Gateway-High-Availability).\n\n## Applicability\n\nUse this review for an SDN multitenant gateway design. Identify the intended gateway function, pool membership, and tenant connection paths. Confirm the current supported deployment requirements before applying the architectural example.\n\n## DSE recommendation\n\nDocument which active gateway failures the proposed standby allocation must cover. Name the tenant connections that would be included in a controlled failover exercise and the acceptable interruption for each. Ask the network owner to review placement and available capacity alongside the gateway count. Preserve the original pool design and assign responsibility for restoring standby capacity after an incident.\n\n## Verification\n\nDuring an approved exercise, record active and standby membership before and after the selected failure. Test representative tenant connections and compare the interruption with the approved objective. Check the restored steady state separately from initial recovery. Retain unsuccessful connections and capacity concerns as findings requiring follow-up.\n\n## Official references\n\n[Microsoft Learn: RAS Gateway High Availability](https://learn.microsoft.com/en-us/windows-server/networking/sdn/technologies/network-function-virtualization/RAS-Gateway-High-Availability). Source reviewed September 8, 2026."
    },
    "json_ld": {
        "@context": "https://schema.org",
        "@graph": [
            {
                "@type": "Organization",
                "@id": "https://dsesecurity.com/#organization",
                "name": "Detection Systems & Engineering",
                "alternateName": "DSE Security",
                "url": "https://dsesecurity.com/",
                "logo": {
                    "@type": "ImageObject",
                    "url": "https://update.dsesecurity.com/assets/dse-logo-20260812.png?v=1.8.20"
                }
            },
            {
                "@type": "Organization",
                "@id": "https://update.dsesecurity.com/#editorial-team",
                "name": "DSE Security Editorial Team",
                "url": "https://update.dsesecurity.com/",
                "parentOrganization": {
                    "@id": "https://dsesecurity.com/#organization"
                }
            },
            {
                "@type": "WebSite",
                "@id": "https://update.dsesecurity.com/#website",
                "name": "DSE Updates",
                "alternateName": "DSE Security Knowledge Hub",
                "url": "https://update.dsesecurity.com/",
                "inLanguage": "en-US",
                "publisher": {
                    "@id": "https://dsesecurity.com/#organization"
                },
                "potentialAction": {
                    "@type": "SearchAction",
                    "target": {
                        "@type": "EntryPoint",
                        "urlTemplate": "https://update.dsesecurity.com/?q={search_term_string}"
                    },
                    "query-input": "required name=search_term_string"
                }
            },
            {
                "@type": "WebPage",
                "@id": "https://update.dsesecurity.com/updates/dse-20260908-008-size-ras-gateway-standby-pools-as-an-explicit-availability-decision/",
                "url": "https://update.dsesecurity.com/updates/dse-20260908-008-size-ras-gateway-standby-pools-as-an-explicit-availability-decision/",
                "isPartOf": {
                    "@id": "https://update.dsesecurity.com/#website"
                },
                "lastReviewed": "2026-09-08"
            },
            {
                "@type": "BreadcrumbList",
                "@id": "https://update.dsesecurity.com/updates/dse-20260908-008-size-ras-gateway-standby-pools-as-an-explicit-availability-decision/#breadcrumbs",
                "itemListElement": [
                    {
                        "@type": "ListItem",
                        "position": 1,
                        "name": "DSE Updates",
                        "item": "https://update.dsesecurity.com/"
                    },
                    {
                        "@type": "ListItem",
                        "position": 2,
                        "name": "Size RAS gateway standby pools as an explicit availability decision",
                        "item": "https://update.dsesecurity.com/updates/dse-20260908-008-size-ras-gateway-standby-pools-as-an-explicit-availability-decision/"
                    }
                ]
            },
            {
                "@type": [
                    "Article",
                    "TechArticle"
                ],
                "@id": "https://update.dsesecurity.com/updates/dse-20260908-008-size-ras-gateway-standby-pools-as-an-explicit-availability-decision/#article",
                "identifier": "https://update.dsesecurity.com/updates/dse-20260908-008-size-ras-gateway-standby-pools-as-an-explicit-availability-decision/",
                "url": "https://update.dsesecurity.com/updates/dse-20260908-008-size-ras-gateway-standby-pools-as-an-explicit-availability-decision/",
                "headline": "Size RAS gateway standby pools as an explicit availability decision",
                "description": "How should active and standby gateway membership be reviewed in an SDN RAS pool?",
                "abstract": "How should active and standby gateway membership be reviewed in an SDN RAS pool?",
                "articleBody": "Source facts\nMicrosoft describes multitenant RAS Gateway as routing traffic between virtual and physical networks for enterprises or service providers. Gateway pools use M active virtual gateways with N standby gateways; N cannot exceed M. In the documented deployment, pools sit behind a software load balancer, and a tenant can have connections ending on different pools or gateways. Microsoft documentation.\nApplicability\nUse this review for an SDN multitenant gateway design. Identify the intended gateway function, pool membership, and tenant connection paths. Confirm the current supported deployment requirements before applying the architectural example.\nDSE recommendation\nDocument which active gateway failures the proposed standby allocation must cover. Name the tenant connections that would be included in a controlled failover exercise and the acceptable interruption for each. Ask the network owner to review placement and available capacity alongside the gateway count. Preserve the original pool design and assign responsibility for restoring standby capacity after an incident.\nVerification\nDuring an approved exercise, record active and standby membership before and after the selected failure. Test representative tenant connections and compare the interruption with the approved objective. Check the restored steady state separately from initial recovery. Retain unsuccessful connections and capacity concerns as findings requiring follow-up.\nOfficial references\nMicrosoft Learn: RAS Gateway High Availability. Source reviewed September 8, 2026.",
                "datePublished": "2026-09-08T18:17:03+00:00",
                "dateModified": "2026-09-08T18:17:13+00:00",
                "mainEntityOfPage": {
                    "@id": "https://update.dsesecurity.com/updates/dse-20260908-008-size-ras-gateway-standby-pools-as-an-explicit-availability-decision/"
                },
                "inLanguage": "en-US",
                "isAccessibleForFree": true,
                "author": {
                    "@type": "Organization",
                    "name": "DSE Security Editorial Team",
                    "url": "https://update.dsesecurity.com/#editorial-team"
                },
                "publisher": {
                    "@id": "https://dsesecurity.com/#organization"
                },
                "image": {
                    "@type": "ImageObject",
                    "@id": "https://update.dsesecurity.com/updates/dse-20260908-008-size-ras-gateway-standby-pools-as-an-explicit-availability-decision/#primaryimage",
                    "url": "https://update.dsesecurity.com/assets/editorial/network-infrastructure-social-v2.jpg?v=1.8.20",
                    "contentUrl": "https://update.dsesecurity.com/assets/editorial/network-infrastructure-social-v2.jpg?v=1.8.20",
                    "width": 1200,
                    "height": 630,
                    "caption": "Size RAS gateway standby pools as an explicit availability decision"
                },
                "articleSection": [
                    "IT",
                    "Networks & Infrastructure"
                ],
                "keywords": [
                    "IT",
                    "Networks & Infrastructure",
                    "Guide",
                    "Information priority"
                ],
                "genre": "Guide",
                "about": [
                    {
                        "@type": "Thing",
                        "name": "IT",
                        "url": "https://update.dsesecurity.com/topic/it/"
                    },
                    {
                        "@type": "Thing",
                        "name": "Networks & Infrastructure",
                        "url": "https://update.dsesecurity.com/topic/networks-infrastructure/"
                    }
                ],
                "wordCount": 211,
                "timeRequired": "PT1M",
                "publishingPrinciples": "https://update.dsesecurity.com/updates/dse-updates-editorial-methodology/",
                "usageInfo": "https://update.dsesecurity.com/usage/",
                "copyrightHolder": {
                    "@id": "https://dsesecurity.com/#organization"
                },
                "copyrightNotice": "Copyright © 2026 Detection Systems & Engineering. All rights reserved.",
                "citation": {
                    "@type": "CreativeWork",
                    "name": "RAS Gateway High Availability",
                    "url": "https://learn.microsoft.com/en-us/windows-server/networking/sdn/technologies/network-function-virtualization/RAS-Gateway-High-Availability"
                }
            }
        ]
    }
}