{
    "api_version": "1",
    "kind": "dse_post",
    "self": "https://update.dsesecurity.com/api/v1/posts/dse-20260908-134-choose-storage-bus-cache-provisioning-mode-before-enabling-the-feature/",
    "item": {
        "id": "https://update.dsesecurity.com/updates/dse-20260908-134-choose-storage-bus-cache-provisioning-mode-before-enabling-the-feature/",
        "slug": "dse-20260908-134-choose-storage-bus-cache-provisioning-mode-before-enabling-the-feature",
        "url": "https://update.dsesecurity.com/updates/dse-20260908-134-choose-storage-bus-cache-provisioning-mode-before-enabling-the-feature/",
        "alternate_urls": {
            "markdown": "https://update.dsesecurity.com/updates/dse-20260908-134-choose-storage-bus-cache-provisioning-mode-before-enabling-the-feature.md",
            "json": "https://update.dsesecurity.com/api/v1/posts/dse-20260908-134-choose-storage-bus-cache-provisioning-mode-before-enabling-the-feature/"
        },
        "title": "Choose Storage bus cache provisioning mode before enabling the feature",
        "summary": "Which Storage bus cache choice must be made before enablement on a standalone server?",
        "format": {
            "slug": "guide",
            "name": "Guide"
        },
        "priority": {
            "slug": "info",
            "name": "Information"
        },
        "featured": false,
        "image": {
            "theme": "network-infrastructure",
            "label": "Networks & infrastructure",
            "alt": "Resilient network core with engineered blue and gold data paths.",
            "card_url": "https://update.dsesecurity.com/assets/editorial/network-infrastructure-card.webp?v=1.8.20",
            "hero_url": "https://update.dsesecurity.com/assets/editorial/network-infrastructure-hero.webp?v=1.8.20",
            "social_url": "https://update.dsesecurity.com/assets/editorial/network-infrastructure-social-v2.jpg?v=1.8.20",
            "width": 2400,
            "height": 1350
        },
        "topics": [
            {
                "slug": "it",
                "name": "IT",
                "url": "https://update.dsesecurity.com/topic/it/"
            },
            {
                "slug": "networks-infrastructure",
                "name": "Networks & Infrastructure",
                "url": "https://update.dsesecurity.com/topic/networks-infrastructure/"
            }
        ],
        "author": {
            "name": "DSE Security Editorial Team",
            "url": "https://update.dsesecurity.com/#editorial-team",
            "type": "Organization"
        },
        "publisher": {
            "name": "Detection Systems & Engineering",
            "url": "https://dsesecurity.com/"
        },
        "published_at": "2026-09-08T18:14:57+00:00",
        "modified_at": "2026-09-08T18:23:27+00:00",
        "reviewed_on": "2026-09-08",
        "reading_minutes": 1,
        "word_count": 206,
        "potentially_affected": "Administrators evaluating Storage bus cache on standalone Windows Server storage.",
        "dse_recommendation": "Write down the intended use of the faster media before enabling the cache.",
        "primary_source": {
            "name": "Storage bus cache on Storage Spaces",
            "url": "https://learn.microsoft.com/en-us/windows-server/storage/storage-spaces/storage-spaces-storage-bus-cache",
            "published_on": null,
            "authority": "Microsoft Learn"
        },
        "publishing_principles": "https://update.dsesecurity.com/updates/dse-updates-editorial-methodology/",
        "usage_info": "https://update.dsesecurity.com/usage/",
        "copyright_notice": "Copyright © 2026 Detection Systems & Engineering. All rights reserved.",
        "content_html": "<h2>Source facts</h2>\n<p>Storage bus cache combines faster and slower media into tiers on a standalone server. Microsoft’s default reserves only part of the faster tier for caching. Provision Mode determines whether all or part of the faster tier is used as cache. Microsoft states that this field cannot be changed after enabling the feature. The instructions require any necessary configuration to be completed before enablement. <a href=\"https://learn.microsoft.com/en-us/windows-server/storage/storage-spaces/storage-spaces-storage-bus-cache\" target=\"_blank\" rel=\"noopener noreferrer\">Microsoft documentation</a>.</p>\n<h2>Applicability</h2>\n<p>Check the exact server release, media combination, installed features, and volume design against the source prerequisites. Distinguish this standalone feature from Storage Spaces Direct caching across cluster nodes.</p>\n<h2>DSE recommendation</h2>\n<p>Write down the intended use of the faster media before enabling the cache. Have the storage owner review the capacity allocated to cache and to workload storage, including the selected Provision Mode. Retain the current disk inventory and approved recovery procedure before changing the storage configuration.</p>\n<h2>Verification</h2>\n<p>Inspect the resulting mode, device roles, and capacity allocation and compare them with the approved design. Measure a representative workload under documented conditions and record any unresolved discrepancy. Do not assume that a successful enablement proves the chosen split meets the application’s capacity or performance needs.</p>\n<h2>Official references</h2>\n<p><a href=\"https://learn.microsoft.com/en-us/windows-server/storage/storage-spaces/storage-spaces-storage-bus-cache\" target=\"_blank\" rel=\"noopener noreferrer\">Microsoft Learn: Storage bus cache on Storage Spaces</a>. Source reviewed September 8, 2026.</p>",
        "content_text": "Source facts\nStorage bus cache combines faster and slower media into tiers on a standalone server. Microsoft’s default reserves only part of the faster tier for caching. Provision Mode determines whether all or part of the faster tier is used as cache. Microsoft states that this field cannot be changed after enabling the feature. The instructions require any necessary configuration to be completed before enablement. Microsoft documentation.\nApplicability\nCheck the exact server release, media combination, installed features, and volume design against the source prerequisites. Distinguish this standalone feature from Storage Spaces Direct caching across cluster nodes.\nDSE recommendation\nWrite down the intended use of the faster media before enabling the cache. Have the storage owner review the capacity allocated to cache and to workload storage, including the selected Provision Mode. Retain the current disk inventory and approved recovery procedure before changing the storage configuration.\nVerification\nInspect the resulting mode, device roles, and capacity allocation and compare them with the approved design. Measure a representative workload under documented conditions and record any unresolved discrepancy. Do not assume that a successful enablement proves the chosen split meets the application’s capacity or performance needs.\nOfficial references\nMicrosoft Learn: Storage bus cache on Storage Spaces. Source reviewed September 8, 2026.",
        "content_markdown": "## Source facts\n\nStorage bus cache combines faster and slower media into tiers on a standalone server. Microsoft’s default reserves only part of the faster tier for caching. Provision Mode determines whether all or part of the faster tier is used as cache. Microsoft states that this field cannot be changed after enabling the feature. The instructions require any necessary configuration to be completed before enablement. [Microsoft documentation](https://learn.microsoft.com/en-us/windows-server/storage/storage-spaces/storage-spaces-storage-bus-cache).\n\n## Applicability\n\nCheck the exact server release, media combination, installed features, and volume design against the source prerequisites. Distinguish this standalone feature from Storage Spaces Direct caching across cluster nodes.\n\n## DSE recommendation\n\nWrite down the intended use of the faster media before enabling the cache. Have the storage owner review the capacity allocated to cache and to workload storage, including the selected Provision Mode. Retain the current disk inventory and approved recovery procedure before changing the storage configuration.\n\n## Verification\n\nInspect the resulting mode, device roles, and capacity allocation and compare them with the approved design. Measure a representative workload under documented conditions and record any unresolved discrepancy. Do not assume that a successful enablement proves the chosen split meets the application’s capacity or performance needs.\n\n## Official references\n\n[Microsoft Learn: Storage bus cache on Storage Spaces](https://learn.microsoft.com/en-us/windows-server/storage/storage-spaces/storage-spaces-storage-bus-cache). Source reviewed September 8, 2026."
    },
    "json_ld": {
        "@context": "https://schema.org",
        "@graph": [
            {
                "@type": "Organization",
                "@id": "https://dsesecurity.com/#organization",
                "name": "Detection Systems & Engineering",
                "alternateName": "DSE Security",
                "url": "https://dsesecurity.com/",
                "logo": {
                    "@type": "ImageObject",
                    "url": "https://update.dsesecurity.com/assets/dse-logo-20260812.png?v=1.8.20"
                }
            },
            {
                "@type": "Organization",
                "@id": "https://update.dsesecurity.com/#editorial-team",
                "name": "DSE Security Editorial Team",
                "url": "https://update.dsesecurity.com/",
                "parentOrganization": {
                    "@id": "https://dsesecurity.com/#organization"
                }
            },
            {
                "@type": "WebSite",
                "@id": "https://update.dsesecurity.com/#website",
                "name": "DSE Updates",
                "alternateName": "DSE Security Knowledge Hub",
                "url": "https://update.dsesecurity.com/",
                "inLanguage": "en-US",
                "publisher": {
                    "@id": "https://dsesecurity.com/#organization"
                },
                "potentialAction": {
                    "@type": "SearchAction",
                    "target": {
                        "@type": "EntryPoint",
                        "urlTemplate": "https://update.dsesecurity.com/?q={search_term_string}"
                    },
                    "query-input": "required name=search_term_string"
                }
            },
            {
                "@type": "WebPage",
                "@id": "https://update.dsesecurity.com/updates/dse-20260908-134-choose-storage-bus-cache-provisioning-mode-before-enabling-the-feature/",
                "url": "https://update.dsesecurity.com/updates/dse-20260908-134-choose-storage-bus-cache-provisioning-mode-before-enabling-the-feature/",
                "isPartOf": {
                    "@id": "https://update.dsesecurity.com/#website"
                },
                "lastReviewed": "2026-09-08"
            },
            {
                "@type": "BreadcrumbList",
                "@id": "https://update.dsesecurity.com/updates/dse-20260908-134-choose-storage-bus-cache-provisioning-mode-before-enabling-the-feature/#breadcrumbs",
                "itemListElement": [
                    {
                        "@type": "ListItem",
                        "position": 1,
                        "name": "DSE Updates",
                        "item": "https://update.dsesecurity.com/"
                    },
                    {
                        "@type": "ListItem",
                        "position": 2,
                        "name": "Choose Storage bus cache provisioning mode before enabling the feature",
                        "item": "https://update.dsesecurity.com/updates/dse-20260908-134-choose-storage-bus-cache-provisioning-mode-before-enabling-the-feature/"
                    }
                ]
            },
            {
                "@type": [
                    "Article",
                    "TechArticle"
                ],
                "@id": "https://update.dsesecurity.com/updates/dse-20260908-134-choose-storage-bus-cache-provisioning-mode-before-enabling-the-feature/#article",
                "identifier": "https://update.dsesecurity.com/updates/dse-20260908-134-choose-storage-bus-cache-provisioning-mode-before-enabling-the-feature/",
                "url": "https://update.dsesecurity.com/updates/dse-20260908-134-choose-storage-bus-cache-provisioning-mode-before-enabling-the-feature/",
                "headline": "Choose Storage bus cache provisioning mode before enabling the feature",
                "description": "Which Storage bus cache choice must be made before enablement on a standalone server?",
                "abstract": "Which Storage bus cache choice must be made before enablement on a standalone server?",
                "articleBody": "Source facts\nStorage bus cache combines faster and slower media into tiers on a standalone server. Microsoft’s default reserves only part of the faster tier for caching. Provision Mode determines whether all or part of the faster tier is used as cache. Microsoft states that this field cannot be changed after enabling the feature. The instructions require any necessary configuration to be completed before enablement. Microsoft documentation.\nApplicability\nCheck the exact server release, media combination, installed features, and volume design against the source prerequisites. Distinguish this standalone feature from Storage Spaces Direct caching across cluster nodes.\nDSE recommendation\nWrite down the intended use of the faster media before enabling the cache. Have the storage owner review the capacity allocated to cache and to workload storage, including the selected Provision Mode. Retain the current disk inventory and approved recovery procedure before changing the storage configuration.\nVerification\nInspect the resulting mode, device roles, and capacity allocation and compare them with the approved design. Measure a representative workload under documented conditions and record any unresolved discrepancy. Do not assume that a successful enablement proves the chosen split meets the application’s capacity or performance needs.\nOfficial references\nMicrosoft Learn: Storage bus cache on Storage Spaces. Source reviewed September 8, 2026.",
                "datePublished": "2026-09-08T18:14:57+00:00",
                "dateModified": "2026-09-08T18:23:27+00:00",
                "mainEntityOfPage": {
                    "@id": "https://update.dsesecurity.com/updates/dse-20260908-134-choose-storage-bus-cache-provisioning-mode-before-enabling-the-feature/"
                },
                "inLanguage": "en-US",
                "isAccessibleForFree": true,
                "author": {
                    "@type": "Organization",
                    "name": "DSE Security Editorial Team",
                    "url": "https://update.dsesecurity.com/#editorial-team"
                },
                "publisher": {
                    "@id": "https://dsesecurity.com/#organization"
                },
                "image": {
                    "@type": "ImageObject",
                    "@id": "https://update.dsesecurity.com/updates/dse-20260908-134-choose-storage-bus-cache-provisioning-mode-before-enabling-the-feature/#primaryimage",
                    "url": "https://update.dsesecurity.com/assets/editorial/network-infrastructure-social-v2.jpg?v=1.8.20",
                    "contentUrl": "https://update.dsesecurity.com/assets/editorial/network-infrastructure-social-v2.jpg?v=1.8.20",
                    "width": 1200,
                    "height": 630,
                    "caption": "Choose Storage bus cache provisioning mode before enabling the feature"
                },
                "articleSection": [
                    "IT",
                    "Networks & Infrastructure"
                ],
                "keywords": [
                    "IT",
                    "Networks & Infrastructure",
                    "Guide",
                    "Information priority"
                ],
                "genre": "Guide",
                "about": [
                    {
                        "@type": "Thing",
                        "name": "IT",
                        "url": "https://update.dsesecurity.com/topic/it/"
                    },
                    {
                        "@type": "Thing",
                        "name": "Networks & Infrastructure",
                        "url": "https://update.dsesecurity.com/topic/networks-infrastructure/"
                    }
                ],
                "wordCount": 206,
                "timeRequired": "PT1M",
                "publishingPrinciples": "https://update.dsesecurity.com/updates/dse-updates-editorial-methodology/",
                "usageInfo": "https://update.dsesecurity.com/usage/",
                "copyrightHolder": {
                    "@id": "https://dsesecurity.com/#organization"
                },
                "copyrightNotice": "Copyright © 2026 Detection Systems & Engineering. All rights reserved.",
                "citation": {
                    "@type": "CreativeWork",
                    "name": "Storage bus cache on Storage Spaces",
                    "url": "https://learn.microsoft.com/en-us/windows-server/storage/storage-spaces/storage-spaces-storage-bus-cache"
                }
            }
        ]
    }
}