{
    "api_version": "1",
    "kind": "dse_post",
    "self": "https://update.dsesecurity.com/api/v1/posts/osha-silica-table-1-drilling-concrete-masonry-installers-exposure-control-plan/",
    "item": {
        "id": "https://update.dsesecurity.com/updates/osha-silica-table-1-drilling-concrete-masonry-installers-exposure-control-plan/",
        "slug": "osha-silica-table-1-drilling-concrete-masonry-installers-exposure-control-plan",
        "url": "https://update.dsesecurity.com/updates/osha-silica-table-1-drilling-concrete-masonry-installers-exposure-control-plan/",
        "alternate_urls": {
            "markdown": "https://update.dsesecurity.com/updates/osha-silica-table-1-drilling-concrete-masonry-installers-exposure-control-plan.md",
            "json": "https://update.dsesecurity.com/api/v1/posts/osha-silica-table-1-drilling-concrete-masonry-installers-exposure-control-plan/"
        },
        "title": "Drilling concrete for cameras and conduit? Use OSHA’s Table 1 drill controls and a written silica exposure plan",
        "summary": "OSHA’s respirable crystalline silica standard for construction lets employers follow Table 1 controls or measure exposure. For handheld and stand-mounted drills, OSHA’s fact sheet describes a shroud with a vacuum dust collection system and a filter of 99 percent or better efficiency, and every covered employer needs a written exposure control plan.",
        "format": {
            "slug": "guide",
            "name": "Guide"
        },
        "priority": {
            "slug": "advisory",
            "name": "Advisory"
        },
        "featured": false,
        "image": {
            "theme": "physical-security",
            "label": "Physical security",
            "alt": "Integrated video surveillance and controlled entry at a modern commercial facility.",
            "card_url": "https://update.dsesecurity.com/assets/editorial/physical-security-card.webp?v=1.8.20",
            "hero_url": "https://update.dsesecurity.com/assets/editorial/physical-security-hero.webp?v=1.8.20",
            "social_url": "https://update.dsesecurity.com/assets/editorial/physical-security-social-v2.jpg?v=1.8.20",
            "width": 2400,
            "height": 1350
        },
        "topics": [
            {
                "slug": "business-continuity",
                "name": "Business Continuity",
                "url": "https://update.dsesecurity.com/topic/business-continuity/"
            },
            {
                "slug": "networks-infrastructure",
                "name": "Networks & Infrastructure",
                "url": "https://update.dsesecurity.com/topic/networks-infrastructure/"
            }
        ],
        "author": {
            "name": "DSE Security Editorial Team",
            "url": "https://update.dsesecurity.com/#editorial-team",
            "type": "Organization"
        },
        "publisher": {
            "name": "Detection Systems & Engineering",
            "url": "https://dsesecurity.com/"
        },
        "published_at": "2026-10-18T21:01:25+00:00",
        "modified_at": "2026-10-18T22:22:08+00:00",
        "reviewed_on": "2026-10-18",
        "reading_minutes": 3,
        "word_count": 442,
        "potentially_affected": "Contractors and technicians who drill, cut or grind concrete, brick, block or stone to mount cameras, readers, panels and conduit, and the supervisors who plan that work.",
        "dse_recommendation": "DSE recommends equipping every hammer drill used on masonry with a shroud and vacuum dust collection system, and keeping a written silica exposure control plan for installation crews.",
        "primary_source": {
            "name": "OSHA — Silica, Crystalline: Construction",
            "url": "https://www.osha.gov/silica-crystalline/construction",
            "published_on": null,
            "authority": "Occupational Safety and Health Administration"
        },
        "publishing_principles": "https://update.dsesecurity.com/updates/dse-updates-editorial-methodology/",
        "usage_info": "https://update.dsesecurity.com/usage/",
        "copyright_notice": "Copyright © 2026 Detection Systems & Engineering. All rights reserved.",
        "content_html": "<p>OSHA’s respirable crystalline silica standard for construction lets employers follow Table 1 controls or measure exposure. For handheld and stand-mounted drills, OSHA’s fact sheet describes a shroud with a vacuum dust collection system and a filter of 99 percent or better efficiency, and every covered employer needs a written exposure control plan.</p>\n<h2>Source facts</h2>\n<p>OSHA’s <a href=\"https://www.osha.gov/silica-crystalline/construction\">construction silica page</a> says its respirable crystalline silica standard requires employers to limit worker exposures, and lets them either use the control methods in Table 1 or measure exposure and choose controls that keep exposures to the permissible exposure limit. Regardless of method, covered construction employers must have a written exposure control plan, designate a competent person, restrict housekeeping practices that expose workers, offer medical exams to workers required to wear a respirator for 30 or more days per year, train workers and keep records.</p>\n<p>OSHA’s <a href=\"https://www.osha.gov/sites/default/files/publications/OSHA_FS-3630.pdf\">fact sheet for handheld and stand-mounted drills</a> says drilling holes in concrete, masonry or other silica-containing materials can generate respirable crystalline silica dust, and describes a vacuum dust collection system with a shroud around the bit, a vacuum providing the tool maker’s recommended airflow or greater, and an air filter of 99 percent or greater efficiency with a filter cleaning mechanism. Dust in drilled holes must be cleaned with a HEPA-filtered vacuum, and compressed air should not be used for cleanup without ventilation that captures the dust.</p>\n<p>The fact sheet says a properly used system can keep dust below the permissible exposure limit of 50 μg/m3 as an 8-hour average, so respiratory protection is not required with it, though extra ventilation may be needed indoors or in enclosed areas. OSHA’s <a href=\"https://www.osha.gov/sites/default/files/publications/OSHA3681.pdf\">standard summary</a> says employers who correctly follow Table 1 are not required to measure exposure for those tasks.</p>\n<h2>Applicability</h2>\n<p>Use this for construction drilling, cutting and grinding on silica-containing materials. Michigan employers fall under MIOSHA, and OSHA says state plans must be at least as effective as OSHA and may differ; check the state rule before relying on federal text.</p>\n<h2>DSE recommendation</h2>\n<p>DSE recommends equipping every hammer drill used on masonry with a shroud and vacuum dust collection system, and keeping a written silica exposure control plan for installation crews. Name a competent person for each crew, add ventilation for indoor drilling, ban dry sweeping and compressed-air cleanup, and cover the plan in job hazard briefings.</p>\n<h2>Verification</h2>\n<p>Inspect drill shrouds, hoses and filters before each job, review the exposure control plan annually, and confirm each technician’s silica training record is current.</p>\n<h2>Official references</h2>\n<p><a href=\"https://www.osha.gov/silica-crystalline/construction\">OSHA — Silica, Crystalline: Construction</a>. <a href=\"https://www.osha.gov/sites/default/files/publications/OSHA_FS-3630.pdf\">OSHA — Control of Silica Dust in Construction: Handheld and Stand-Mounted Drills (FS-3630)</a>. <a href=\"https://www.osha.gov/sites/default/files/publications/OSHA3681.pdf\">OSHA — Respirable Crystalline Silica Standard for Construction fact sheet</a>. Reviewed October 18, 2026.</p>",
        "content_text": "OSHA’s respirable crystalline silica standard for construction lets employers follow Table 1 controls or measure exposure. For handheld and stand-mounted drills, OSHA’s fact sheet describes a shroud with a vacuum dust collection system and a filter of 99 percent or better efficiency, and every covered employer needs a written exposure control plan.\nSource facts\nOSHA’s construction silica page says its respirable crystalline silica standard requires employers to limit worker exposures, and lets them either use the control methods in Table 1 or measure exposure and choose controls that keep exposures to the permissible exposure limit. Regardless of method, covered construction employers must have a written exposure control plan, designate a competent person, restrict housekeeping practices that expose workers, offer medical exams to workers required to wear a respirator for 30 or more days per year, train workers and keep records.\nOSHA’s fact sheet for handheld and stand-mounted drills says drilling holes in concrete, masonry or other silica-containing materials can generate respirable crystalline silica dust, and describes a vacuum dust collection system with a shroud around the bit, a vacuum providing the tool maker’s recommended airflow or greater, and an air filter of 99 percent or greater efficiency with a filter cleaning mechanism. Dust in drilled holes must be cleaned with a HEPA-filtered vacuum, and compressed air should not be used for cleanup without ventilation that captures the dust.\nThe fact sheet says a properly used system can keep dust below the permissible exposure limit of 50 μg/m3 as an 8-hour average, so respiratory protection is not required with it, though extra ventilation may be needed indoors or in enclosed areas. OSHA’s standard summary says employers who correctly follow Table 1 are not required to measure exposure for those tasks.\nApplicability\nUse this for construction drilling, cutting and grinding on silica-containing materials. Michigan employers fall under MIOSHA, and OSHA says state plans must be at least as effective as OSHA and may differ; check the state rule before relying on federal text.\nDSE recommendation\nDSE recommends equipping every hammer drill used on masonry with a shroud and vacuum dust collection system, and keeping a written silica exposure control plan for installation crews. Name a competent person for each crew, add ventilation for indoor drilling, ban dry sweeping and compressed-air cleanup, and cover the plan in job hazard briefings.\nVerification\nInspect drill shrouds, hoses and filters before each job, review the exposure control plan annually, and confirm each technician’s silica training record is current.\nOfficial references\nOSHA — Silica, Crystalline: Construction. OSHA — Control of Silica Dust in Construction: Handheld and Stand-Mounted Drills (FS-3630). OSHA — Respirable Crystalline Silica Standard for Construction fact sheet. Reviewed October 18, 2026.",
        "content_markdown": "OSHA’s respirable crystalline silica standard for construction lets employers follow Table 1 controls or measure exposure. For handheld and stand-mounted drills, OSHA’s fact sheet describes a shroud with a vacuum dust collection system and a filter of 99 percent or better efficiency, and every covered employer needs a written exposure control plan.\n\n## Source facts\n\nOSHA’s [construction silica page](https://www.osha.gov/silica-crystalline/construction) says its respirable crystalline silica standard requires employers to limit worker exposures, and lets them either use the control methods in Table 1 or measure exposure and choose controls that keep exposures to the permissible exposure limit. Regardless of method, covered construction employers must have a written exposure control plan, designate a competent person, restrict housekeeping practices that expose workers, offer medical exams to workers required to wear a respirator for 30 or more days per year, train workers and keep records.\n\nOSHA’s [fact sheet for handheld and stand-mounted drills](https://www.osha.gov/sites/default/files/publications/OSHA_FS-3630.pdf) says drilling holes in concrete, masonry or other silica-containing materials can generate respirable crystalline silica dust, and describes a vacuum dust collection system with a shroud around the bit, a vacuum providing the tool maker’s recommended airflow or greater, and an air filter of 99 percent or greater efficiency with a filter cleaning mechanism. Dust in drilled holes must be cleaned with a HEPA-filtered vacuum, and compressed air should not be used for cleanup without ventilation that captures the dust.\n\nThe fact sheet says a properly used system can keep dust below the permissible exposure limit of 50 μg/m3 as an 8-hour average, so respiratory protection is not required with it, though extra ventilation may be needed indoors or in enclosed areas. OSHA’s [standard summary](https://www.osha.gov/sites/default/files/publications/OSHA3681.pdf) says employers who correctly follow Table 1 are not required to measure exposure for those tasks.\n\n## Applicability\n\nUse this for construction drilling, cutting and grinding on silica-containing materials. Michigan employers fall under MIOSHA, and OSHA says state plans must be at least as effective as OSHA and may differ; check the state rule before relying on federal text.\n\n## DSE recommendation\n\nDSE recommends equipping every hammer drill used on masonry with a shroud and vacuum dust collection system, and keeping a written silica exposure control plan for installation crews. Name a competent person for each crew, add ventilation for indoor drilling, ban dry sweeping and compressed-air cleanup, and cover the plan in job hazard briefings.\n\n## Verification\n\nInspect drill shrouds, hoses and filters before each job, review the exposure control plan annually, and confirm each technician’s silica training record is current.\n\n## Official references\n\n[OSHA — Silica, Crystalline: Construction](https://www.osha.gov/silica-crystalline/construction). [OSHA — Control of Silica Dust in Construction: Handheld and Stand-Mounted Drills (FS-3630)](https://www.osha.gov/sites/default/files/publications/OSHA_FS-3630.pdf). [OSHA — Respirable Crystalline Silica Standard for Construction fact sheet](https://www.osha.gov/sites/default/files/publications/OSHA3681.pdf). Reviewed October 18, 2026."
    },
    "json_ld": {
        "@context": "https://schema.org",
        "@graph": [
            {
                "@type": "Organization",
                "@id": "https://dsesecurity.com/#organization",
                "name": "Detection Systems & Engineering",
                "alternateName": "DSE Security",
                "url": "https://dsesecurity.com/",
                "logo": {
                    "@type": "ImageObject",
                    "url": "https://update.dsesecurity.com/assets/dse-logo-20260812.png?v=1.8.20"
                }
            },
            {
                "@type": "Organization",
                "@id": "https://update.dsesecurity.com/#editorial-team",
                "name": "DSE Security Editorial Team",
                "url": "https://update.dsesecurity.com/",
                "parentOrganization": {
                    "@id": "https://dsesecurity.com/#organization"
                }
            },
            {
                "@type": "WebSite",
                "@id": "https://update.dsesecurity.com/#website",
                "name": "DSE Updates",
                "alternateName": "DSE Security Knowledge Hub",
                "url": "https://update.dsesecurity.com/",
                "inLanguage": "en-US",
                "publisher": {
                    "@id": "https://dsesecurity.com/#organization"
                },
                "potentialAction": {
                    "@type": "SearchAction",
                    "target": {
                        "@type": "EntryPoint",
                        "urlTemplate": "https://update.dsesecurity.com/?q={search_term_string}"
                    },
                    "query-input": "required name=search_term_string"
                }
            },
            {
                "@type": "WebPage",
                "@id": "https://update.dsesecurity.com/updates/osha-silica-table-1-drilling-concrete-masonry-installers-exposure-control-plan/",
                "url": "https://update.dsesecurity.com/updates/osha-silica-table-1-drilling-concrete-masonry-installers-exposure-control-plan/",
                "isPartOf": {
                    "@id": "https://update.dsesecurity.com/#website"
                },
                "lastReviewed": "2026-10-18"
            },
            {
                "@type": "BreadcrumbList",
                "@id": "https://update.dsesecurity.com/updates/osha-silica-table-1-drilling-concrete-masonry-installers-exposure-control-plan/#breadcrumbs",
                "itemListElement": [
                    {
                        "@type": "ListItem",
                        "position": 1,
                        "name": "DSE Updates",
                        "item": "https://update.dsesecurity.com/"
                    },
                    {
                        "@type": "ListItem",
                        "position": 2,
                        "name": "Drilling concrete for cameras and conduit? Use OSHA’s Table 1 drill controls and a written silica exposure plan",
                        "item": "https://update.dsesecurity.com/updates/osha-silica-table-1-drilling-concrete-masonry-installers-exposure-control-plan/"
                    }
                ]
            },
            {
                "@type": [
                    "Article",
                    "TechArticle"
                ],
                "@id": "https://update.dsesecurity.com/updates/osha-silica-table-1-drilling-concrete-masonry-installers-exposure-control-plan/#article",
                "identifier": "https://update.dsesecurity.com/updates/osha-silica-table-1-drilling-concrete-masonry-installers-exposure-control-plan/",
                "url": "https://update.dsesecurity.com/updates/osha-silica-table-1-drilling-concrete-masonry-installers-exposure-control-plan/",
                "headline": "Drilling concrete for cameras and conduit? Use OSHA’s Table 1 drill controls and a written silica exposure plan",
                "description": "OSHA’s respirable crystalline silica standard for construction lets employers follow Table 1 controls or measure exposure. For handheld and…",
                "abstract": "OSHA’s respirable crystalline silica standard for construction lets employers follow Table 1 controls or measure exposure. For handheld and stand-mounted drills, OSHA’s fact sheet describes a shroud with a vacuum dust collection system and a filter of 99 percent or better efficiency, and every covered employer needs a written exposure control plan.",
                "articleBody": "OSHA’s respirable crystalline silica standard for construction lets employers follow Table 1 controls or measure exposure. For handheld and stand-mounted drills, OSHA’s fact sheet describes a shroud with a vacuum dust collection system and a filter of 99 percent or better efficiency, and every covered employer needs a written exposure control plan.\nSource facts\nOSHA’s construction silica page says its respirable crystalline silica standard requires employers to limit worker exposures, and lets them either use the control methods in Table 1 or measure exposure and choose controls that keep exposures to the permissible exposure limit. Regardless of method, covered construction employers must have a written exposure control plan, designate a competent person, restrict housekeeping practices that expose workers, offer medical exams to workers required to wear a respirator for 30 or more days per year, train workers and keep records.\nOSHA’s fact sheet for handheld and stand-mounted drills says drilling holes in concrete, masonry or other silica-containing materials can generate respirable crystalline silica dust, and describes a vacuum dust collection system with a shroud around the bit, a vacuum providing the tool maker’s recommended airflow or greater, and an air filter of 99 percent or greater efficiency with a filter cleaning mechanism. Dust in drilled holes must be cleaned with a HEPA-filtered vacuum, and compressed air should not be used for cleanup without ventilation that captures the dust.\nThe fact sheet says a properly used system can keep dust below the permissible exposure limit of 50 μg/m3 as an 8-hour average, so respiratory protection is not required with it, though extra ventilation may be needed indoors or in enclosed areas. OSHA’s standard summary says employers who correctly follow Table 1 are not required to measure exposure for those tasks.\nApplicability\nUse this for construction drilling, cutting and grinding on silica-containing materials. Michigan employers fall under MIOSHA, and OSHA says state plans must be at least as effective as OSHA and may differ; check the state rule before relying on federal text.\nDSE recommendation\nDSE recommends equipping every hammer drill used on masonry with a shroud and vacuum dust collection system, and keeping a written silica exposure control plan for installation crews. Name a competent person for each crew, add ventilation for indoor drilling, ban dry sweeping and compressed-air cleanup, and cover the plan in job hazard briefings.\nVerification\nInspect drill shrouds, hoses and filters before each job, review the exposure control plan annually, and confirm each technician’s silica training record is current.\nOfficial references\nOSHA — Silica, Crystalline: Construction. OSHA — Control of Silica Dust in Construction: Handheld and Stand-Mounted Drills (FS-3630). OSHA — Respirable Crystalline Silica Standard for Construction fact sheet. Reviewed October 18, 2026.",
                "datePublished": "2026-10-18T21:01:25+00:00",
                "dateModified": "2026-10-18T22:22:08+00:00",
                "mainEntityOfPage": {
                    "@id": "https://update.dsesecurity.com/updates/osha-silica-table-1-drilling-concrete-masonry-installers-exposure-control-plan/"
                },
                "inLanguage": "en-US",
                "isAccessibleForFree": true,
                "author": {
                    "@type": "Organization",
                    "name": "DSE Security Editorial Team",
                    "url": "https://update.dsesecurity.com/#editorial-team"
                },
                "publisher": {
                    "@id": "https://dsesecurity.com/#organization"
                },
                "image": {
                    "@type": "ImageObject",
                    "@id": "https://update.dsesecurity.com/updates/osha-silica-table-1-drilling-concrete-masonry-installers-exposure-control-plan/#primaryimage",
                    "url": "https://update.dsesecurity.com/assets/editorial/physical-security-social-v2.jpg?v=1.8.20",
                    "contentUrl": "https://update.dsesecurity.com/assets/editorial/physical-security-social-v2.jpg?v=1.8.20",
                    "width": 1200,
                    "height": 630,
                    "caption": "Drilling concrete for cameras and conduit? Use OSHA’s Table 1 drill controls and a written silica exposure plan"
                },
                "articleSection": [
                    "Business Continuity",
                    "Networks & Infrastructure"
                ],
                "keywords": [
                    "Business Continuity",
                    "Networks & Infrastructure",
                    "Guide",
                    "Advisory priority"
                ],
                "genre": "Guide",
                "about": [
                    {
                        "@type": "Thing",
                        "name": "Business Continuity",
                        "url": "https://update.dsesecurity.com/topic/business-continuity/"
                    },
                    {
                        "@type": "Thing",
                        "name": "Networks & Infrastructure",
                        "url": "https://update.dsesecurity.com/topic/networks-infrastructure/"
                    }
                ],
                "wordCount": 442,
                "timeRequired": "PT3M",
                "publishingPrinciples": "https://update.dsesecurity.com/updates/dse-updates-editorial-methodology/",
                "usageInfo": "https://update.dsesecurity.com/usage/",
                "copyrightHolder": {
                    "@id": "https://dsesecurity.com/#organization"
                },
                "copyrightNotice": "Copyright © 2026 Detection Systems & Engineering. All rights reserved.",
                "citation": {
                    "@type": "CreativeWork",
                    "name": "OSHA — Silica, Crystalline: Construction",
                    "url": "https://www.osha.gov/silica-crystalline/construction"
                }
            }
        ]
    }
}