# Test automatic access doors in power-off and emergency modes

> Accessibility provisions address automatic and power-assisted doors with power on and off, controls, and some breakout openings. Coordinate access control with the full door assembly.

- Canonical URL: https://update.dsesecurity.com/updates/test-automatic-access-doors-in-power-off-and-emergency-modes/
- Publisher: Detection Systems & Engineering (DSE Security)
- Author: DSE Security Editorial Team
- Published: 2026-08-25T21:35:51+00:00
- Modified: 2026-08-25T21:36:17+00:00
- Last reviewed by DSE: 2026-08-25
- Resource type: Checklist
- DSE priority: Important
- Topics: Access Control, Business Continuity
- Reading time: 2 minutes

## What you need to know

Accessibility provisions address automatic and power-assisted doors with power on and off, controls, and some breakout openings. Coordinate access control with the full door assembly.

## Potentially affected

Entrances combining automatic or power-assisted operators with card readers, locks, request-to-exit devices, fire alarm interfaces, or standby power.

## DSE recommendation

Commission the complete doorway in normal, power-loss, standby, fire-alarm, and approved emergency states with accessibility and life-safety authorities involved.

## Article

Bottom line: a powered opening test does not accept an automatic access-controlled doorway. The assembly must be evaluated in the power and emergency states that alter operator, lock, sensor, breakout, and egress behavior.

## Source fact: the ADA standards address powered and unpowered conditions

Section 404.3 of the [2010 ADA Standards — Automatic and Power-Assisted Doors and Gates](https://www.access-board.gov/ada/chapter/ch04/#4043-automatic-and-power-assisted-doors-and-gates) addresses automatic and power-assisted doors and gates. It includes clear-width requirements with power on and off, placement of manually operated controls outside the door swing, and a breakout-opening requirement in specified egress situations when standby power is absent. It also references standards for automatic and power-assisted pedestrian doors.

Those provisions make the access-control system one component of a regulated opening. Lock release, operator power, door swing, sensors, and emergency interfaces must be tested as an integrated assembly.

## Source boundary and applicability

The Access Board page is an authoritative accessibility source, but it is not a complete code analysis or approval for a specific doorway. Enforceable ADA requirements, adopted building and fire codes, referenced door standards, occupancy, egress role, local amendments, and the authority having jurisdiction determine applicability. This article is not legal or code advice.

## Applicability questions

- Is the opening part of an accessible route or required means of egress?

- What operator, lock, latch, closer, sensor, and access-control equipment form the assembly?

- Is standby power provided, and which components remain energized?

- What states are commanded by fire alarm, emergency release, lockdown, or power failure?

- Can required controls be reached without entering the moving door’s swing or hazard zone?

## DSE recommendation: commission a doorway state matrix

The following steps are DSE recommendations based on the cited source.

Have the architect, door specialist, access-control designer, accessibility lead, fire/life-safety authority, and owner identify applicable requirements. Create a matrix for normal access, authorized activation, denied access, loss of building power, standby power, fire alarm, emergency release, lockdown where permitted, and restoration. For each state, define operator motion, lock and latch condition, clear width, manual force, breakout behavior, alarm, monitoring, and responsible authority.

Test with approved procedures that do not compromise occupied-building egress. Verify that restoration does not leave the door unlocked, trapped, faulted, or moving unexpectedly. Correct one system only after checking its effect on the complete opening.

## Verification and evidence

Retain approved drawings, hardware and power schedules, applicable-code determination, state matrix, inspection and test reports, measurements, alarm and PACS logs, video of test motion where authorized, deficiency tickets, and authority sign-off. Re-test after changes to locks, operators, controls, fire alarm, standby power, or software logic.

## Official references

- [2010 ADA Standards, Section 404.3 — Automatic and Power-Assisted Doors and Gates](https://www.access-board.gov/ada/chapter/ch04/#4043-automatic-and-power-assisted-doors-and-gates) – United States Access Board

## Primary reference

- Name: 2010 ADA Standards, Section 404.3 — Automatic and Power-Assisted Doors and Gates
- Authority: www.access-board.gov
- URL: https://www.access-board.gov/ada/chapter/ch04/#4043-automatic-and-power-assisted-doors-and-gates
- Source publication date: Not stated by the source

## Citation and use