What you need to know
Stage compacted SQLite outputs and accept only completed, checked recovery artifacts.
Potentially affected
This applies to SQLite versions supporting the documented VACUUM INTO behavior. It addresses output acceptance and destination handling, rather than the incremental Online Backup API or every application's recovery procedure.
DSE recommendation
DSE recommends creating each output at a unique staging path and recording command completion before promoting it into the backup inventory.
Stage compacted SQLite outputs and accept only completed, checked recovery artifacts.
Source facts
SQLite VACUUM INTO writes a compacted copy to a separate output file while leaving the source database unchanged. The output is a consistent snapshot when the operation completes, but interruption by power loss or unplanned shutdown can leave it incomplete and corrupt. The named output must not already exist unless it is empty. The documentation also describes synchronization of completed output when the source connection’s synchronous setting is NORMAL or FULL, subject to functioning operating-system and storage guarantees.
Source: SQLite — VACUUM.
Applicability
This applies to SQLite versions supporting the documented VACUUM INTO behavior. It addresses output acceptance and destination handling, rather than the incremental Online Backup API or every application’s recovery procedure.
DSE recommendation
DSE recommends creating each output at a unique staging path and recording command completion before promoting it into the backup inventory. Have the application owner confirm that its SQLite release and connection settings match the procedure. Treat an interrupted output as unaccepted until it is replaced by a completed run and reviewed. Keep destination ownership and free-space checks explicit. Avoid overwriting the only known recovery copy while experimenting with a compacted export or maintenance schedule.
Verification
With disposable data, generate an output at an unused path, retain the completion result, and open that output independently for integrity and application checks. Rehearse interrupted-run handling separately. Confirm the backup inventory accepts only the completed artifact and keeps older recovery copies until acceptance is finished.
Official reference
SQLite — VACUUM. Reviewed October 15, 2026.
Review the official source
SQLite — VACUUM · Verified October 15, 2026
Need help applying this guidance safely?
DSE can help confirm applicability, protect service continuity, and validate the result across physical security and IT systems.
Talk with DSE